FDC Rescue Products

FDC Rescue Products

Municipal Hose

Glotek

Hotstop

Powerline

Standpipe 600

Reeltex
RXL-800
Supplyline
Tidalwave 600
Ultra 2000
Ultra Force 2000
XL-800

Forestry Hose

Draftex
Econoflo
EconoForest
Firestream
Hotline
Hotstop
Reeltex
Source-Line
Spec-187
Staflo

 Hydro Hose Testers

 Coupling Machines & Couplers

T.P.U. Lining Data
Hose Weave Types
Encap V Hypalon
Encap Data

 

STAFLO® 

A 100% filament polyester, TPU elastomer lined weeping forestry hose. Lightweight, easily packed, and handled. The weepage rate is 11.8 to 18.6 oz/ft/minute at 100 PSIG (350 to 550 ml/0.3 m/minute at 700 kPa). This single jacket forestry hose meets or exceeds ULC S-519-1.

Length: Up to 100' (30,5 m).
 

 

  

STAFLO® specifications

 
bullet

The hose shall be a single jacket construction with 100% virgin filament polyester.

bullet

There shall also be a minimum of 11.0 filler yarns per inch in the jacket.

bullet

The thickness of the lining shall be 0.011" (279 µm) minimum and it shall be constructed of extruded T.P.U. elastomer.

bullet

The hose service temperature range shall be -60°F to 140°F (-51°C to 60°C).

bullet

FM abrasion test of 1,000 cycles minimum.

bullet

At 300 PSIG (2100 kPa), its elongation shall not exceed 6% of the initial hose length, it shall not warp more than 20 inches (51 cm) and should not rise from the test table.

bullet

The hose shall not twist more than 10 turns per 100 ft (30,5 m) while at 300 PSIG (2100 kPa).

bullet

Minimum service test pressure of 150 PSIG (1050 kPa).

bullet

Minimum proof test pressure of 300 PSIG (2100 kPa).

bullet

Minimum straight burst test pressure of 900 PSIG (6300 kPa).

bullet

The hose while curved to a radius of 27" (69 cm) shall not burst at less than 900 PSIG (6300 kPa).

bullet

The leakage shall be consistent and uniform throughout the length of the hose. The leakage rate per 1 foot of hose at 250 PSIG (1750 kPa) shall be 0.68oz/ft/min (66 ml/m/min) for the 1" (25 mm) and 1.03 oz/ft/min (100 ml/m/min) for the 1˝" (38 mm).

bullet

Meets or exceeds ULC S-519 specifications.

 

Physical properties
Hose SizeSpec NumberCoupling bowl sizeWeight per 50 ftCoil Diameter per 50 ftMinimum Kink Burst Test Pressure
1"
(25 mm)
21601 3/16"
(30.2 mm)
4 lbs
(1.8 kg)
10"
(25 cm)
500 PSIG
(3500 kPa)
1 1/2"
(38 mm)
21651 11/16"
(42.9 mm)
6 lbs
(2.7 kg)
10"
(25 cm)
500 PSIG
(3500 kPa)

Contact

      FDC Rescue Products
for your
RESCUE Needs                           Phoenix Area 623-463-2235
or Toll Free 877-FDC-RESC